CHARACTERISTICS OF PERMANENT PACEMAKER IMPLANTATION HAVE AN INDICATIONS FOR PACEMAKER IMPLANTATION AT THE VIETNAM NATIONAL HEART INSTITUTE
Main Article Content
Abstract
Objective: To study the situation and characteristics of permanent pacemakers implantation indicated for pacemaker implantation at the Vietnam National Heart Institute. Methods: A prospective, cross-sectional descriptive study on the patients who received the pacemaker implantation at the Vietnam National Heart Institute during the period from August 1, 2019 to March 30, 2020. Results: Study on 294 patients who permanent pacemaker implantation at the Vietnam National Heart Institute have results: Indication for pacemaker implantation and location of atrial and ventricular electrodes: The rate of patients have an indication for pacemaker implantation with atrioventricular block was the highest (46.6%), sinus node failure was 42.9%, Brugada syndrome (2.4%), ventricular arrhythmias (4.8%), heart failure (3.3%), machine replacement 19%. Among 246 implanted right ventricular electrodes, the implantation position in the Interventricular septum accounts for the highest percentage (87.0%). Among the 207 implanted right atrial electrodes, the most implanted position was the right atrium (94.2%), the left ventricular electrode position was placed mainly in the lateral branch of the coronary sinus vein. Rate of pacemaker types: The rate of implantation of 2-chamber pacemaker is the highest (67.7%), 1-chamber pacemaker is 23.8%, Implantable cardioverter defibrillator (ICD) machine accounts for 5.8%, Resynchronization Therapy (CRT) machine is 2.7%. the number of patients having to replace the machine accounts for 19%. There were 8 patients (2.7%) upgraded from 1- chamber pacemaker to 2-chamber pacemaker. Some pacing parameters.The mean of right ventricular pacing threshold was 0.74 ± 0.22 V, the lowest was 0.2 V, the highest was 2.0 V. The mean of right atrial pacing threshold was 0.93 ± 0.31, the lowest was 0.4 V, The highest is 2.4V, the average of left ventricular pacing threshold was 1.10 ± 0.62 V, the lowest is 0.6 V, and the highest is 2.6V.
Article Details
Keywords
Chỉ định cấy máy tạo nhịp, vị trí điện cực, các loại máy tạo nhịp, thông số tạo nhịp
References
Most read articles by the same author(s)
- Nguyen Thi Hanh, Chu Dung Si, STUDY ON THE INFLUENCE OF SOME PERSONAL AND SOCIAL FACTORS ON LIFE QUALITY IN PATIENTS WITH MYOCARDIAL INFARCTION AFTER CORONARY INTERVENTION , Vietnam Journal of Physiology: Vol. 26 No. 2 (2022)
- Sĩ Chu Dũng, CLINICAL AND SUBCLINICAL CHARACTERISTICS IN PATIENTS HAVE AN INDICATIONS FOR PERMANET PACEMAKER IMPLANTATION AT THE VIETNAM NATIONAL HEART INSTITUTE , Vietnam Journal of Physiology: Vol. 27 No. 2 (2023)
- Sĩ Chu Dũng, ẢNH HƢỞNG MỘT SỐ YẾU TỐ NGUY CƠ ĐẾN THỰC TRẠNG RỐI LOẠN ĐÔNG MÁU VÀ NGUY CƠ XUẤT HUYẾT DO QUÁ LIỀU CHỐNG ĐÔNG KHÁNG VITAMIN K , Vietnam Journal of Physiology: Vol. 27 No. 2 (2023)
- Sĩ Chu Dũng, THE DIFFERENT ELECTROPHYSIOLOGICAL CHARACTERISTICS IN PATIENTS WITH WOLFF - PARKINSON - WHITE SYNDROME BETWEEN THOSE WITH AND WITHOUT ATRIAL FIBRILLATION , Vietnam Journal of Physiology: Vol. 27 No. 2 (2023)
Similar Articles
- Ngoc-Thao PHAM, Huy Thông Nguyễn, ASSESSMENT OF QUALITY OF LIFE AND SOME RELATED FACTORS IN PATIENTS WITH METABOLIC SYNDROME , Vietnam Journal of Physiology: Vol. 29 No. 1 (2025)
You may also start an advanced similarity search for this article.